In many locations from chemistry laboratories to industrial services, to be able to guarantee the security of life and property against a possible fireplace hazard, extinguishing methods are used in addition to detection and alarm methods. It can additionally be extraordinarily essential that the extinguishing techniques installed may be triggered by the hearth extinguishing control panel, in order to remove a attainable fireplace with early intervention.
In order to meet these wants, and with 35 years of sectoral knowledge and expertise, Mavili Elektronik provides:
Maxlogic Conventional Fire Extinguishing Control Panel working in accordance with the cross-zone detection precept;
Maxlogic Extinguishing Status Indicator Unit, which allows the distant efficiency of the indications and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which allows the extinguishing process to be began manually and remotely; and
to ensure that the extinguishing process may be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these gadgets are produced using surface-mount know-how and are aimed at making the automation of the extinguishing system and fireplace and gas detection system perfect.
Image copyright: Mavili
Mavili Elektronik develops its merchandise by at all times contemplating the needs of the set up. In cases that require the mixing of the extinguishing system with the intelligent addressable hearth detection system, it offers options via the monitoring modules that even have a ‘supervised’ possibility.
Supervised monitoring modules play an necessary position in controlling the continuity of the cable connection between the loop and the extinguishing system. เกจ์วัดแรงดัน to detect a attainable open or short circuit in the wiring between the contact monitoring modules and the peripheral systems could cause disruption of the triggering, with potentially critical consequences. For this purpose, when selecting monitoring modules, it must be taken into consideration that they have supervised features.
Image copyright: Mavili
Since Maxlogic clever addressable fire detection and alarm management panels are constantly communicating with ‘supervise’ contact monitoring modules linked to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it simpler to watch conditions similar to open circuits and short circuits which will happen in the system. Many tasks can be performed within the fire extinguishing installation, such because the management and monitoring of all valves that can interrupt the circulate of water, water circulate alarm switches, strain change, and electric or diesel hearth pumps.
By including two contact monitoring modules to two separate relay outputs situated above the Maxlogic Conventional Fire Extinguishing Control Panel, one of many modules can be utilized to manage errors and the other to control the fireplace state of affairs, monitoring and control of the extinguishing system by way of an intelligent addressable fire detection and alarm system may be performed effectively.
For more info, go to www.mavili.com.tr/en