In many places from chemistry laboratories to industrial amenities, to be able to ensure the security of life and property against a possible hearth hazard, extinguishing methods are used along with detection and alarm methods. It is also extraordinarily necessary that the extinguishing methods put in can be triggered by the fireplace extinguishing control panel, to be able to remove a possible fire with early intervention.
In order to satisfy these needs, and with 35 years of sectoral information and expertise, Mavili Elektronik presents:
Maxlogic Conventional Fire Extinguishing Control Panel operating in accordance with the cross-zone detection precept;
Maxlogic Extinguishing Status Indicator Unit, which permits the remote efficiency of the symptoms and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which allows the extinguishing course of to be began manually and remotely; and
to ensure that the extinguishing process could be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these gadgets are produced utilizing surface-mount technology and are geared toward making the automation of the extinguishing system and fire and fuel detection system perfect.
เกจวัดแรง : Mavili
Mavili Elektronik develops its products by always contemplating the needs of the installation. In เกจวัดแรงดันภาษาอังกฤษ that require the mixing of the extinguishing system with the clever addressable fire detection system, it offers options through the monitoring modules that also have a ‘supervised’ possibility.
Supervised monitoring modules play an important position in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a attainable open or brief circuit in the wiring between the contact monitoring modules and the peripheral systems can cause disruption of the triggering, with potentially crucial penalties. For this reason, when choosing monitoring modules, it ought to be taken into account that they have supervised features.
Image copyright: Mavili
Since Maxlogic clever addressable fire detection and alarm management panels are continuously speaking with ‘supervise’ contact monitoring modules linked to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it easier to watch conditions such as open circuits and brief circuits that will happen within the system. Many tasks could be carried out within the fireplace extinguishing installation, such as the control and monitoring of all valves that may interrupt the move of water, water circulate alarm switches, strain switch, and electric or diesel fire pumps.
By including two contact monitoring modules to two separate relay outputs situated above the Maxlogic Conventional Fire Extinguishing Control Panel, one of many modules can be utilized to control errors and the opposite to regulate the fireplace scenario, monitoring and control of the extinguishing system via an intelligent addressable hearth detection and alarm system may be carried out effectively.
For extra data, go to www.mavili.com.tr/en
Share